Fuel level sensor "STRELA" with digital RS232 interface is used to connect the devices with RS232 interface (MODBUS or Omnicomm data transfer protocol).
The sensors can be used in tanks of vehicles, tractors and other machinery whith nominal on-board network voltage 12 or 24V.
Protocol parameters: up to 19200 bit per second, 8 bit, 1 stop bit. Resolution - up to 65535 points per length.
Sensor is customizable and can be connected to PC or laptop to make settings using Universal service adapter (USA 2.2).
You can configure the following parametres using our configuration software:
- Change the ID of sensor;
- Make sensors calibration for full and empty tubes;
- Turn on/of the thermal compensation;
- Change the average type and interval;
- Change the output value;
- Turn on/off the output data transmission;
- If it's required make the tank calibration table and set it into sensors memory etc.
STRELA D232 | |
Fuel volume 0% | 0 |
Fuel volume 100% | can be set |
Supply voltage, V | 10-30 |
Maximum load curent, mA | 50 |
Precision of level measurements, % from length | ±0.1 |
Limits of additional conventional error, % | no more as 1.0 |
Self-testing codes | yes |
Operational temperature ,°С | -40 - +65 |
Mean time to failure | no less as 12500 hr |
Ingress protection rating | IP66 |
Consumed power, W | <0.2 |
Overall dimensions, mm | L x 70 x 70 |
Continuous work time | not limited |
All RS232 sensors must be calibrated before installation !!!