Universal service adapter USA 2.2 is used:
- To connect STRELA sensors with interfaces RS-232, RS-485, TTL UART to a personal computer. The device supports any data protocols, the physical implementation of which is based on RS-232, RS-485, TTL UART interfaces.
- For measurement of frequency, voltage and current consumption of STRELA sensors connected to the adapter using special software.
- To generate a special signal "Calibration" to calibrate STRELA sensors with voltage and frequency output.
- To set Summator light, FLS mediation device, Counter-indicator etc
Main technical characteristics of communication interfaces.
Name | Value |
RS232 interface | |
Input signal voltage range | ±30V |
Output signal voltage range | ±5V |
Used data transmission lines | RS-232-Tx, RS-232-Rx, common line |
RS485 interface | |
Input signal voltage range | -7...+12V |
Output signal voltage range | 0.....+5V |
Length of communication line with external device | no more as 1200m. |
Quantity of sensors in network | no more as 32 |
Used data transmission lines | RS-485-B, RS-485-A |
TTL UART | |
Input voltage range (Rx UART) | 0...+5V |
Output voltage range (Tx UART) | 0...+5V |
Length of communication line with external device | up to 3m. |
Frequency measurement | |
Range of measured frequencies | 10...30000Hz |
Absolute measuring error in the range from 10 to 10000 Hz | ±1Hz |
Reduced measuring error in the range from 10 to 30000 Hz | 0.5% |
Threshold voltage | 2.5V |
Measuring time | 1s |
Voltage measurement | |
Range of measured voltages | 0...15V |
Reduced measuring error | 0.5% |
Measurement of current consumption | |
Maximum current | 100mA |
Reduced measuring error | 1% |
Characteristics of the power line | |
Rated output voltage | 12V |
Maximum current | 100mA |
Other characteristics | |
Source of power | USB port |
Maximum current consumption | 200mA |
Galvanic isolation | up to 1500V |
Baud rate | up to 115200 bits per second |